LG LMU180HHV.AWGBEUS Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Split-System-Klimaanlagen LG LMU180HHV.AWGBEUS herunter. LG LMU180HHV.AWGBEUS Owner's manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 55
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Multi Type
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it
thoroughly.
INSTALLATION MANUAL
AIR
CONDITIONER
P/NO : MFL68280104
www.lg.com
http://www.lghvac.com
ENGLISH
FRANÇAIS ESPAÑOL
1,MFL68280104,영어 2017. 7. 10. 오후 4:11 페이지 1
Seitenansicht 0
1 2 3 4 5 6 ... 54 55

Inhaltsverzeichnis

Seite 1 - CONDITIONER

Multi TypePlease read this installation manual completely before installing the product.Installation work must be performed in accordance with the nat

Seite 2 - INSTRUCTIONS

10 Multi Air ConditionerInstallation of Indoor, Outdoor UnitSeaside Applications and Installation1. Air conditioners should not be installed in areas

Seite 3 - TABLE OF CONTENTS

Installation Manual 11Installation of Indoor, Outdoor Unit ENGLISHSeasonal Wind And Cautions In Winter- Sufficient measures are required in a snow

Seite 4 - [Ceiling Cassette Type]

12 Multi Air ConditionerInstallation of Indoor, Outdoor Unit Multi Piping TypePiping length and elevationh2h1ABMultiple Piping TypeCAUTION: Capacity

Seite 5 - Safety Precautions

Installation Manual 13Installation of Indoor, Outdoor Unit Distributor Piping Typeh1CBranch PipeMain PipeDistributorDistributorABh2CAUTION: Capacit

Seite 6 - 6 Multi Air Conditioner

14 Multi Air ConditionerInstallation # Standard / Artcool Mirror Type1. Prepare the indoor unit's piping and drainhose for installation through

Seite 7 - Installation Manual 7

Installation Manual 15Installation ENGLISH# Standard Libero / Artcool Libero Type1. Pull the screw cap at the bottom of theindoor unit2. Remove the

Seite 8 - Select the best location

16 Multi Air ConditionerInstallation Connecting the piping to the indoor unitand drain hose to drain pipe.1. Align the center of the pipes and suffi

Seite 9 - Rooftop Installations:

Installation Manual 17Installation ENGLISHWrap the insulation material around the con-necting portion.1. Overlap the connection pipe insulation and

Seite 10 - 10 Multi Air Conditioner

18 Multi Air ConditionerInstallation The wall you select should be strong and solid enough to prevent vibration1. Mount the installation plate on th

Seite 11 - Installation Manual 11

Installation Manual 19Installation ENGLISHWiring Connection1. Connect the wires to the terminals on the con-trol board individually according to th

Seite 12 - Piping length and elevation

FLEX MULTI SPLIT INSTALLATION INSTRUCTIONSDo not turn on the breaker or power under condition that front panel, cabinet, top cover, control box cover

Seite 13 - Distributor Piping Type

20 Multi Air ConditionerInstallation [Ceiling Cassette Type]Ceiling dimension and hanging bolt locationLevel gaugeCeilingCeiling boardUnit: mm(inch)

Seite 14 - Installation

Installation Manual 21Installation ENGLISHSet screw ofpaper model (4 pieces)Paper modelfor installationCeiling board150mm(5-7/8 inch)Ceiling boardC

Seite 15 - Installation plate

22 Multi Air ConditionerInstallation Installation of Wired Remote Controller(Optional)12323<Wire guide grooves>1. Please fix tightly using pro

Seite 16 - Bad case

Installation Manual 23Installation ENGLISHWallSideWallSideWallSideWallSide<Connecting order><Separating order>3. Please fix remote cont

Seite 17 - Piping for

24 Multi Air ConditionerInstallation Installation of Decorative PanelThe decorative panel has its installation direction.Before installing the decor

Seite 18 - Installation of filters

Installation Manual 25Installation ENGLISH5. Fit the corner covers.6. Open two screws of control panel cover.7. Connect one display connector and t

Seite 19 - Cable retainer

26 Multi Air ConditionerInstallation CAUTION: Install certainly the decorative panel.Cool air leakage causes sweating.  Water drops fall.Air condi

Seite 20 - Level gauge

Installation Manual 27Installation ENGLISHCAUTION : The supplied flexi-ble drain hose should not becurved, neither screwed. Thecurved or screwed ho

Seite 21 - Conduit connection

28 Multi Air ConditionerInstallation Attention1. Possible drain-head height is up to700mm(27 9/16 inch). So, it must be in-stalled below 700mm(27 9/

Seite 22

Installation Manual 29Flaring Work and Connection of Piping ENGLISHFlaring Work and Connection of PipingFlaring workMain cause of gas leakage is de

Seite 23 - Unit side

Installation Manual 3Multi Air Conditioner Installation ManualTABLE OF CONTENTSInstallation Parts Provided ...

Seite 24 - Hook clip

30 Multi Air ConditionerFlaring Work and Connection of Piping Align the center of the piping and sufficiently tighten the flare nut by hand.Connecti

Seite 25 - CN-DISPLA

Installation Manual 31Flaring Work and Connection of Piping ENGLISH• For the units with capacity more than 36kBtu/hclass, the installation piping i

Seite 26 - Drain Piping

32 Multi Air ConditionerFlaring Work and Connection of Piping Viewed from point Ain direction of arrowHorizontalplaneGas PipeModelPMBL5620Ø19.05Ø19.

Seite 27 - Feed water

Installation Manual 33Flaring Work and Connection of Piping ENGLISHInstallation• This unit may be installed suspended from the ceiling or mounted o

Seite 28 - Attention

34 Multi Air ConditionerFlaring Work and Connection of Piping : • This unit has two different installation types:(1) Ceiling-suspended type and (2)

Seite 29 - Flaring work

Installation Manual 35Connecting the Cable between Indoor Unit, Distributor Unit and Outdoor Unit ENGLISHConnecting the Cable between Indoor Unit,

Seite 30 - 30 Multi Air Conditioner

36 Multi Air ConditionerConnecting the Cable between Indoor Unit, Distributor Unit and Outdoor Unit • Connect refrigerant pipes and connection wires

Seite 31 - (Figure3)

Installation Manual 37Connecting the Cable between Indoor Unit, Distributor Unit and Outdoor Unit ENGLISH(1) Remove the control cover. Loosen the t

Seite 32 - 32 Multi Air Conditioner

38 Multi Air ConditionerConnecting the Cable between Indoor Unit, Distributor Unit and Outdoor Unit Connect the cable to the Outdoor unit.1. Remove

Seite 33

Installation Manual 39Connecting the Cable between Indoor Unit, Distributor Unit and Outdoor Unit ENGLISH36,42kBtu/h classPower cord terminalConnec

Seite 34 - Installation of The Main Unit

4 Multi Air ConditionerInstallation Parts Provided Installation Parts Provided [Wall mounted / ART COOL Mirror][Ceiling Concealed Duct Type][Ceili

Seite 35 - Use a circuit breaker

40 Multi Air ConditionerConnecting the Cable between Indoor Unit, Distributor Unit and Outdoor Unit (1) Remove the side panel and knockouts of condu

Seite 36 - Power wire(Ground wire)

Installation Manual 41Checking the Drainage, Insulating the Pipe and Special Piping ApplicationsENGLISHInsulating the Pipe and Special Piping Applica

Seite 37 - Installation Manual 37

Air Purging and EvacuationAir and moisture remaining in the refrigerant system have undesirable effects as indicated below.1. Pressure in the system r

Seite 38 - 30kBtu/h class

Installation Manual 43Air Purging and Evacuation ENGLISH1. Connect the charge hose end described inthe preceding steps to the vacuum pump toevacuat

Seite 39 - 36,42kBtu/h class

44 Multi Air ConditionerChargingImportant:If you are ever uncertain of the unit charge, reclaim, evacuate and weigh in the correct charge usingthe cha

Seite 40 - Strand wire

Installation Manual 45Charging ENGLISHh If the total additional charge value after calculation comes out to be negative, then do not consideradditi

Seite 41 - Checking the drainage

46 Multi Air ConditionerInstallation PI485Fix the PI485 PCB as shown in Fig.Detailed installation method refer to PI485 Installation Manual. 18,24,30k

Seite 42 - Air Purging and Evacuation

Installation Manual 47Test RunningENGLISHPrepare remote controlRemove the battery cover by pulling it accordingto the arrow direction.Insert new batt

Seite 43 - Evacuation

48 Multi Air ConditionerFunctionIf you set the Dip Switch when power is on, the change in setting is not applicable. The changing set-ting is enabled

Seite 44 - Charging

Installation Manual 49Function ENGLISH18,24,30kBtu/h classSW136,42kBtu/h classDIP-SW01D12345678910Adding the refrigerant in winter.Setting Procedur

Seite 45 - Distributor type Models

Installation Manual 5Product Introduction ENGLISHh The figure can be changed according to model. To prevent the injury of the user or other people

Seite 46 - Installation PI485

50 Multi Air ConditionerFunction Saving Power Consumption operation is the function whichenables efficient operation by lowering the maximum powerco

Seite 47 - Test Running

Installation Manual 51Function ENGLISHSaving Power Consumption Current level.Night Quiet Mode operation lowers the noise level of the outdoor unit

Seite 48 - Function

52 Multi Air ConditionerFunction Setting Procedure1. Set the Dip Switch as follow after shutting the power source down.2. Reset the power.Mode Lock

Seite 49 - Forced Cooling Operation

Installation Manual 53Function ENGLISHIt is useful to check the cycle data without LGMV.Operating MethodWhenever you push the Tact Switch, the cycl

Seite 50 - Saving Power Consumption

54 Multi Air ConditionerMax Combination CapacityMax Combination CapacityMulti Piping TypeCapacity(Btu/h class)Max Room No.Combination Indoor Capacity(

Seite 51 - Night Quiet Mode

USPlease call the installing contractor of your product, as warranty service will beprovided by them.CANADAService call Number # : (888) LG Canada, (8

Seite 52 - Mode Lock

6 Multi Air ConditionerSafety PrecautionsDo not install the product at a place that thereis concern of falling down.• Otherwise, it may result in pers

Seite 53 - Operating Method

Installation Manual 7Safety Precautions ENGLISHCAUTIONn InstallationInstall the drain hose to ensure that draincan be securely done.• Otherwise, it

Seite 54 - Max Combination Capacity

8 Multi Air ConditionerSafety PrecautionsInstallation of Indoor, Outdoor UnitRead completely, then follow step by step.Indoor unit1. Do not have any h

Seite 55

Installation Manual 9Installation of Indoor, Outdoor Unit ENGLISHOutdoor unit1. If an awning is built over the unit to prevent di-rect sunlight or

Kommentare zu diesen Handbüchern

Keine Kommentare