LG BSNQ096B3U0 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Nein LG BSNQ096B3U0 herunter. LG BSNQ096B3U0 Owner's manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
LG
Air Conditioner
INSTALLATION MANUAL
LG
Type : Wall Mounted
http://www.lgservice.com
IMPORTANT
• Please read this instruction manual completely before
installing the product.
• When the power cord is damaged, replacement should be
performed by authorized personnel only.
• Installation work must be performed in accordance with
the national wiring standards by authorized personnel
only.
• Please retain this installation manual for future reference
after reading it thoroughly.
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - Air Conditioner

LGAir ConditionerINSTALLATION MANUALLGType : Wall Mountedhttp://www.lgservice.comIMPORTANT• Please read this instruction manual completely before inst

Seite 2 - CONTENTS

InstallationInstallation Manual 10Piping Length and Elevation9k Ø9.52 3/8 Ø 6.35 1/4 7.5 10 2 15 20 Pipe SizeCapacity(Btu/h)GAS L

Seite 3 - Safety Precautions

Indoor unitThe wall you select should be strong and solidenough to prevent vibration1. Mount the installation plate on the wall with type "A"

Seite 4 - ■ Operation

Installation Flaring WorkMain cause for gas leakage is due to defect of flaring work. Carry out correct flaring work in thefollowing procedure.Cut th

Seite 5 - ■ Installation

InstallationCheck1. Compare the ared work with the gure by.2. If a ared section is defective, cut it o anddo aring work again.1.Pull the screw ca

Seite 6 - Introduction

InstallationInstallation Information. For right piping. Follow the instruction below.Good case• Press on the tubing cover and unfold the tubing to do

Seite 7

InstallationInstallation of Indoor Unit1. Hook the indoor unit onto the upper portion ofthe installation plate.( engage the three hooksat the top of t

Seite 8 - Installation Map

Installation3. Tape the tubing pipe, drain hose and the connection cable. Be sure that the drain hose is locatedat the lowest side of the bundle. Loca

Seite 9 - Select the best Location

InstallationWrap the insulation material around theconnecting portion.1. Overlap the connection pipe insulationmaterial and the indoor unit pipe insul

Seite 10 - Piping Length and Elevation

1. Align the center of the pipings and sufficientlytighten the flare nut by hand.2. Finally, tighten the flare nut with torquewrench until the wrench

Seite 11 - Drill a Hole in the Wall

InstallationIndoor unitConnect the cable to the indoor unit by connecting the wires to the terminals on the control boardindividually according to the

Seite 12 - Flaring Work

2 Air conditonerAir Conditioner Installation ManualCONTENTSSafety Precautions...3Introduction ...

Seite 13 - Connecting the Piping

InstallationOutdoor unit1. Connect the wires to the terminals on thecontrol board individually.2. Secure the cable onto the control board withthe cord

Seite 14 - Bad case

Installation Checking the DrainageTo check the drainage.1. Pour a glass of water on the evaporator.2. Ensure the water flows through the drainhose o

Seite 15 - Installation of Indoor Unit

InstallationForming the PipingForm the piping by wrapping theconnecting portion of the indoor unitwith insulation material and secure itwith two kinds

Seite 16 - 16 Air conditioner

Installation Air PurgingThe air and moisture remaining in the refrigerant system have undesirable effects as indicated below.1. Pressure in the syst

Seite 17 - IQVWDOODWLRQ0DQXDO17

InstallationSoap water method1. Remove the caps from the 2-way and 3-way valves.2. Remove the service-port cap from the 3-way valve.3. Apply a soap wa

Seite 18 - Outdoor unit

Installation 1. Check that all tubing and wiring are properly connected.2. Check that the gas and liquid side service valves are fully open.• Ration

Seite 19 - Connecting the Cables

InstallationIf the actual pressure is higher than shown, the system is most likely over-charged, and chargeshould be removed. If the actual pressure a

Seite 20 - Use a circuit breake

InstallationInstallation guide at the seaside1. Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas,

Seite 21 - Checking the Drainage

P/No.: MFL62106406 After reading this manual, keep it in a place easily accessible to the user forfuture reference.

Seite 22 - Forming the Piping

IQVWDOODWLRQ0DQXDO 3Safety Precautions To prevent the injury of the user or other people and property damage, the following instructionsmust be foll

Seite 23 - Air Purging

Safety Precautions Do not install the product at a place wherethere is concern of falling down.• Otherwise, it may result in personal injury.Use cau

Seite 24 - Finishing the Job

,QVWDOODWLRQ0DQXDO 5Safety Precautions InstallationInstall the drain hose to ensure that draincan be securely done.• Otherwise, it may cause wate

Seite 25 - Test Running

The gure of product can be dierent according to the type of model.Introduction This symbol alerts you to the risk of electric shock.This symbol al

Seite 26 - Evaluation of the performance

Type "A" screwType "C" screwType "B" screwThe feature can be changed according a type of model.Remote control holderInst

Seite 27 - IQVWDOODWLRQ0DQXDO27

InstallationInstallation MapBase PlateAir Outlet VentsAir Inlet VentsVinyl tape (Wide)• Apply after carrying out a drainage test.• To carry out the

Seite 28 - P/No.: MFL62106406

Select the best Location More than 15cm.More than5cm.More than 2.3m.More than5cm.Install the indoor unit on the wall where the height from the floor i