LG ARUN048GSS4.EWGBLUS Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Split-System-Klimaanlagen LG ARUN048GSS4.EWGBLUS herunter. LG ARUN038GSS4.EWGBLUS Owner's manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 29
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
P/NO : MFL67798024
INSTALLATION MANUAL
AIR
CONDITIONER
www.lg.com
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it
thoroughly.
Original instruction
ENGLISH
FRANÇAIS
ESPAÑOL
Seitenansicht 0
1 2 3 4 5 6 ... 28 29

Inhaltsverzeichnis

Seite 1 - CONDITIONER

P/NO : MFL67798024 INSTALLATION MANUALAIRCONDITIONERwww.lg.comPlease read this installation manual completely before installing the product.Installati

Seite 2 - IMPORTANT SAFETY INSTRUC

10ENGLISH1 Always use the nitrogen.(not use oxygen, carbon dioxide, anda Chevron gas): Please use the following nitrogen pressure0.02MPa(2.9psi) Oxyg

Seite 3 - TABLE OF CONTENTS

11ENGLISH- Pipe connections can be done on the front side or on the side accord-ing to the installation environments.- Be sure to let 0.2kgf/cm2(0.284

Seite 4 - ALTERNATIVE REFRIGERANT R410A

12ENGLISHTotal pipe length = A+B+C+D+a+b+c+d+e ≤ 300m(984ft)LLongest pipe length Equivalent pipe length(*)A+B+C+D+e ≤ 150m(492ft) A+B+C+D+e ≤ 175m(574

Seite 5 - Air inlet grille

13ENGLISH• * : Assume equivalent pipe length of Y branch to be 0.5m(1.6ft),that of header to be 1m(3.3ft), calculation purpose• Indoor Unit should b

Seite 6 - or more

14ENGLISHIndoor Unit ConnectionIndoor Unit connecting pipe from branch (a,b,c,d,e,f)Indoor Unit capacity[kW(Btu/h)]Liquid pipe[mm(inch)]Gas pipe [mm(i

Seite 7 - Secure minimum intake area

15ENGLISH1st1st1stMain pipeDistribution2nd2nd3rd3ndMain pipeDistribution1st3rd3rd main pipe distribution2ndHorizontal Distribution• When the number of

Seite 8 - INSTALLATION

16ENGLISH• Joints between branch and pipe should be sealed with the tape in-cluded in each kit.• Any cap pipe should be insulated using the insulator

Seite 9 - R=0.4~0.8

17ENGLISHNOTE!If the ambient temperature differs between the time when pressure is appliedand when the pressure drop is checked, apply the following c

Seite 10 - Nitrogen substitution method

18ENGLISHBe sure to give insulation work to refrigerant piping by covering liquidpipe and gas pipe separately with enough thickness heat-resistant pol

Seite 11 - Liquid/Gas pipes

19ENGLISH2-Core Shield CableMulti-Core CableRemotecontrolRemotecontrolRemotecontrolRemotecontrolIndoorUnitOutdoor UnitOutdoor UnitIndoorUnitIndoorUnit

Seite 12 - Y branch method

2ENGLISH• Do not cool excessively indoors. This may be harmful for your healthand may consume more electricity.• Block sunlight with blinds or curta

Seite 13 - [Unit:m(ft)]

20ENGLISHNOTE!• The figures are based on assumed length of parallel cabling upto 100m(328ft). For length in excess of 100m(328ft) the figureswill have

Seite 14 - Refrigerant charging

- About more information of IO Module, please refer to IO Modulemanual.CAUTIONBe sure to turn off outdoor unit power before installation.!++※Pictures

Seite 15 - Pinched pipe

Example) Group number setting 1stnumber indicate the group number2nd number point out indoor unit numberSODU.B SODU.A IDU.B IDU.A CEN.B CEN.A DRY1 DRY

Seite 16 - Y branch pipe

CAUTION• Request installer to set the function during installation. • If ODU RPM changes, cooling capacity may go down.!Master unit PCB DIP switch on

Seite 17 - Gas side

24ENGLISHMaster unit PCB DIP switch on : No.5Select the mode using ‘▶’, ‘◀’ Button :“Func” Push the ‘●’ buttonSelect the Function using ‘▶’, ‘◀’ Butto

Seite 18 - ELECTRICAL WIRING

25ENGLISHError No. of CompressorError No.Error No. of UnitRepeatDisplay Title Cause of ErrorIndoor unit related error0 1 -Air temperature sensor of in

Seite 19 - Side panel

26ENGLISHDisplay Title Cause of Error5 0 1Omitting connection of R, S, T power of Outdoor Unit Omitting connection of outdoor unit5 1 1Excessive capac

Seite 20 - Pull Box(Installer Option)

27ENGLISHCalculate minimum room capacityCalculate room capacity by regarding a portion as one room or thesmaller room.- With partition and with openin

Seite 21

CAUTION• Air conditioners should not be installed in areas wherecorrosive gases, such as acid or alkaline gas, are produced.• Do not install the produ

Seite 22 - B(D) A(C)

US1. Please call the installing contractor of your product, as warranty service will be provided by them.2. If you have service issues that have not b

Seite 23

3CAUTIONInstallation• Always check for gas (refrigerant) leakage after installation or repair of product.- Low refrigerant levels may cause failure of

Seite 24 - Target pressure adjusting

4ENGLISHThe foundation must be level evenOutdoor unit foundation workAvoid short circuits and ensure sufficient space is allowed for serviceInstallatio

Seite 25 - Self-Diagnosis Function

5ENGLISHAir inlet grille700[Unit : mm]Turn the air outlet side toward thebuilding's wall, fence or windbreak screen.WARNINGFix the outdoor unit f

Seite 26

6ENGLISHIn case of obstacles on the discharge side1. Stand alone installation500(19-5/8) or more500(19-5/8) or less1000 (39-1/4) or more500(19-5/8) or

Seite 27 - CAUTION FOR REFRIGERANT LEAK

7ENGLISHSeasonal wind and cautions in winter• Sufficient measures are required in a snow area or severe cold areain winter so that product can be oper

Seite 28 - Product information

8ENGLISH• Fix the unit tightly with bolts as shown below so that unit will not falldown due to earthquake or gust.• Use the H-beam support as a base s

Seite 29

9ENGLISHFlaring work- Carry out flaring work using flaring tool as shown below.Firmly hold copper tube in a bar(or die) as indicated dimension in thet

Kommentare zu diesen Handbüchern

Keine Kommentare