LG HB9522AGF Bedienungsanleitung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 23
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
5.4 Regulation for natural gas
The hob has been adjusted for natural gas at a pressure of
1.0kPa.
To allow the unit to work with this type of gas, perform the same
operations described in paragraph “5.3 Regulation for ULPG”, but
choose the nozzles and regulate the primary air for natural gas, as
shown in the following table and in paragraph “5.5 Regulation of
primary air”. After the regulations have been carried out, restore the
seals with sealing wax or equivalent material.
14
Instructions for the installer
NG – 1.0 kPa
Nominal gas
Consumption
(MJ/h)
Injector
(mm)
Burner
Auxiliary
Semi-rapid
Rapid
Rapid large
Fish pan
Wok
4.8
5.9
8
11.4
11.4
15
0.98
1.10
1.25
1.50
1.50
1.70
Seitenansicht 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 22 23

Kommentare zu diesen Handbüchern

Keine Kommentare