ACP
Advanced Control Platform
(PQCPA11A0E, PQCPB11A0E)
Installation/Owner's Manual
LG
Caution
• Read this manual thoroughly before installing the product.
• Only the certified professional should install this product.
• Keep this manual for referring during the operation later.
Seitenansicht 0
1 2 3 4 5 6 ... 162 163

Inhaltsverzeichnis

Seite 1 - Advanced Control Platform

ACPAdvanced Control Platform(PQCPA11A0E, PQCPB11A0E)Installation/Owner's ManualLGCaution• Read this manual thoroughly before installing the produ

Seite 2 - Contents

ACP1-31. ACP Functions & SpecificationInterconnecting with the simple central controllerThe 16-room simple central controller can be interconnecte

Seite 3 - ...3-1

3. ACP operation by using the LG ACCSACP3-18FilterOperation modeThe Lock function of the ventilator can be set not by the user individually but by cen

Seite 4 - Note for safety

3. ACP operation by using the LG ACCSInstallation/Owner's Manual3-19Air flowIt controls the air flow. The types of air flow to set are as follows

Seite 5 - ■ When installing

3. ACP operation by using the LG ACCSACP3-20LockIt sets the lock function of the ventilator. When the lock function is set, the ventilator can not bec

Seite 6 - ■ When using

3. ACP operation by using the LG ACCSInstallation/Owner's Manual3-21Setting the scheduleIt is the function to perform the reserved operation at t

Seite 7

3. ACP operation by using the LG ACCSACP3-22Pattern setup button and Mode change buttonThe schedule set by the user should be stored and applied as pa

Seite 8 - Functions of ACP

3. ACP operation by using the LG ACCSInstallation/Owner's Manual3-23Mode change buttonThe schedule set by the user should be stored and applied a

Seite 9 - Internet

3. ACP operation by using the LG ACCSACP3-24Select Air conditioner group & Air conditioner windowIt displays the list of the air conditioner group

Seite 10 - (0.0) (0.1) (0.F)

Installation/Owner's Manual3-253. ACP operation by using the LG ACCSSchedule control setup windowIt displays the list of the air conditioner grou

Seite 11 - Denomination of ACP

ACP3-263. ACP operation by using the LG ACCSIt controls the air flow. The types of air flow to set are as follows:It sets the air direction of the cur

Seite 12

Installation/Owner's Manual3-273. ACP operation by using the LG ACCSSet the desired indoor temperature of the air conditioner. The desired temper

Seite 13 - Components of ACP

Installation/Owner's Manual1-41. ACP Functions & SpecificationDenomination of ACPLG-NET 1MENU/SELECTTXRXLG-NET 2TXRXLG-NET 3TXRXLG-NET 4TXRXE

Seite 14 - Hardware Specification of ACP

ACP3-283. ACP operation by using the LG ACCSDelete All buttonApply & Cancel the schedule buttonSave the setting buttonSave the setting button &

Seite 15 - 2. Installing ACP

Installation/Owner's Manual3-293. ACP operation by using the LG ACCSException handling schedule buttonIt is the function excluding the specified

Seite 16 - Before installing the ACP

ACP3-303. ACP operation by using the LG ACCSException handling listDate selection windowThe exception handling list displays thecurrently set exceptio

Seite 17 - Using the hub

Installation/Owner's Manual3-313. ACP operation by using the LG ACCSException handling schedule display windowStop All windowThe method to specif

Seite 18 - Not using the hub

ACP3-323. ACP operation by using the LG ACCSThis section describes the method for setting the schedule and the exception handling schedulebased on the

Seite 19

Installation/Owner's Manual3-333. ACP operation by using the LG ACCS2. Specify the pattern to save the schedule. In this example, the schedule is

Seite 20

ACP3-343. ACP operation by using the LG ACCS4. Now, specify the operation for the schedule to perform. Set 'Cooling operation' as operation,

Seite 21

Installation/Owner's Manual3-353. ACP operation by using the LG ACCS6. Select the time to apply the schedule. At the schedule setup window at the

Seite 22

ACP3-363. ACP operation by using the LG ACCS8. Now, press [Setup mode] button to switch to the view mode. When you click each air conditionername of t

Seite 23 - Group No. Indoor Unit No

Installation/Owner's Manual3-373. ACP operation by using the LG ACCSSetting the exception handling scheduleThe method to set the exception handli

Seite 24

ACP1-5Note: External input/output signal terminal9 external input signal terminal and 10 external output signal terminal are configured at thePQCPB11A

Seite 25

ACP3-383. ACP operation by using the LG ACCS2. Select the data for adding the exceptional date from the calendar. And then, when you enter theexceptio

Seite 26 - Setting the PI485 DIP switch

Installation/Owner's Manual3-393. ACP operation by using the LG ACCS4. Now, apply the schedule to the exception handling schedule. First, check t

Seite 27 - Note: PCB part number

ACP3-403. ACP operation by using the LG ACCS6. Select the target to which the exception handling schedule is applied. Here, because it is applied toal

Seite 28 - Connecting the 2PIN connector

Installation/Owner's Manual3-413. ACP operation by using the LG ACCS8. Select the time to apply the schedule. At the schedule setup window at the

Seite 29 - L1 2 3 4

ACP3-423. ACP operation by using the LG ACCS10. Now, press [Save the setting] button to save the set exception handling schedule. When you click[Save

Seite 30

Installation/Owner's Manual3-433. ACP operation by using the LG ACCS12. When setting the exception handling schedule is completed, click [Exit th

Seite 31

ACP3-443. ACP operation by using the LG ACCSControlling the peak operation ratioIt maintains the consumed power to be kept lower than or equal to the

Seite 32 - Note: Checking the LGAP Label

Installation/Owner's Manual3-453. ACP operation by using the LG ACCSIn order to control the peak operation ratio, click 'Peak power' me

Seite 33

ACP3-463. ACP operation by using the LG ACCSWattage monitorThe following peak control setting information and operation information are displayed at t

Seite 34 - Connecting RS485 cable to ACP

Installation/Owner's Manual3-473. ACP operation by using the LG ACCSOperation switching periodIt displays the period for stopping the peak operat

Seite 35

Installation/Owner's Manual1-61. ACP Functions & SpecificationComponents of ACPThe following components are contained within the packaging bo

Seite 36

ACP3-483. ACP operation by using the LG ACCSDesired powerIt sets the desired wattage in kW per hour to operate the peakoperation function. It can be a

Seite 37 - : Cross cable

3. ACP operation by using the LG ACCSPeak excluded air conditionerPress [Peak excluded air conditioner] to set the air conditioner not to applythe pea

Seite 38

ACP3-503. ACP operation by using the LG ACCSSaving the settingIt saves the setting values of the peak operationratio control up to now.When you press

Seite 39 - Configuring the ACP network

Installation/Owner's Manual3-513. ACP operation by using the LG ACCSControlling the demand powerIt maintains the consumed power to be kept lower

Seite 40 - Turning on the ACP

ACP3-523. ACP operation by using the LG ACCSIn order to control the demand power, click 'Demand power' menu at the top of the LG ACCS. Wheny

Seite 41

Installation/Owner's Manual3-533. ACP operation by using the LG ACCSWattage monitorThe following demand control setting information and operation

Seite 42

ACP3-543. ACP operation by using the LG ACCSSetting the current operation status and the power The graph for displaying the current operation status a

Seite 43 - Setting the IP address

Installation/Owner's Manual3-553. ACP operation by using the LG ACCSSetting the power control (text)The setup item to set the wattage in kW or %

Seite 44 - Setting the gateway address

ACP3-563. ACP operation by using the LG ACCSMonitoring the air conditioner statusYou can see the operation status and the error status of each air con

Seite 45 - Setting the netmask address

Installation/Owner's Manual3-573. ACP operation by using the LG ACCSItem DescriptionTemperature lock Whether to set the temperature lock function

Seite 46

ACP1-71. ACP Functions & SpecificationHardware Specification of ACPItem DescriptionCPU PXA255-400MHz XscaleRAM 128MB (32x4) SDRAMROM • 512KB NOR F

Seite 47

ACP3-583. ACP operation by using the LG ACCSReviewing the error historyThe LG ACCS saves and records the information of the error occurred from all in

Seite 48 - Selecting Peak or Demand

Installation/Owner's Manual3-593. ACP operation by using the LG ACCSQuerying the error history1Saving and Printing2You can set and query the info

Seite 49

ACP3-603. ACP operation by using the LG ACCSError history list3It displays the history list ofthe errors occurred within thequery period.The type of o

Seite 50 - Note: How to use the LG ACCS

Installation/Owner's Manual3-613. ACP operation by using the LG ACCSReviewing the wattage (incteconnecting with the power display)The LG ACCS off

Seite 51

ACP3-623. ACP operation by using the LG ACCSIn order to use the power display interconnection function to check the wattage, click 'Wattage'

Seite 52

Installation/Owner's Manual3-633. ACP operation by using the LG ACCSDisplaying the wattage query periodWattage by indoor unit listGroup listIt di

Seite 53

ACP3-643. ACP operation by using the LG ACCSQuery period displayDetailed history for each air conditionerClick button to display the detailedhistory

Seite 54

Installation/Owner's Manual3-653. ACP operation by using the LG ACCS'End' calendarApply & Cancel buttonThe end date of the query pe

Seite 55

ACP3-663. ACP operation by using the LG ACCSSetting the systemFor the following cases, the air conditioner or the ventilator should be registered at o

Seite 56 - Setting error history display

Installation/Owner's Manual3-673. ACP operation by using the LG ACCSIn order to register, delete or modify the air conditioner at the system, cli

Seite 57 - Configuring the ACCS access

Installation/Owner's Manual2-12. Installing ACPThis chapter describes how to install the ACP to use.In order to use the ACP, the environment for

Seite 58 - Check whether to

ACP3-683. ACP operation by using the LG ACCSGroup input windowA new group is added or the information of the existing group can be changed or deleted

Seite 59

Installation/Owner's Manual3-693. ACP operation by using the LG ACCSAir conditioner (or ventilator) information input window and Temporary saving

Seite 60

ACP3-703. ACP operation by using the LG ACCSThe information to set at the air conditioner (or ventilator) is as follows:TypeType of indoor unit or ven

Seite 61

Installation/Owner's Manual3-713. ACP operation by using the LG ACCSTemporary saving windowIt is convenient to use this window to move the indoor

Seite 62 - ACCS is completed

ACP3-723. ACP operation by using the LG ACCSG/W Number Leave as it is with not modified.Outdoor unit number Enter the outdoor unit number. It should n

Seite 63

3. ACP operation by using the LG ACCSInstallation/Owner's Manual3-73Group number Enter the ventilator group number. The ventilator group number m

Seite 64 - Note: ACP access IP

3. ACP operation by using the LG ACCSACP3-74Entering the administrator information5The administrator information can beentered at 'System setup&a

Seite 65

3. ACP operation by using the LG ACCSInstallation/Owner's Manual3-75Last save state button & Save button[Last save state] button and [Save] b

Seite 66

ACP3-763. ACP operation by using the LG ACCSWhen you click [Save] button, the windowfor confirming to execute the command isdisplayed. Click [Confirm]

Seite 67

Installation/Owner's Manual3-773. ACP operation by using the LG ACCSNote: Procedure for setting the system (air conditioiner andventilator)1. Cli

Seite 68

ACP2-22. Installing ACPBefore installing the ACPACP provides 4 RS485 ports to connect the indoor unit. Maximum of 16 units can be connected toPI485 f

Seite 69 - Modify the Setting value

ACP4-14. Reference4. ReferenceTroubleshootingIf any unexpected problem is occurred when using the ACP, see the following list to find out the solution

Seite 70

Installation/Owner's Manual4-24. Referencetinylogin traceroutebusybox stupid-ftpdBash net-tools boa http serverSysvinit Inetutils e2fsprogsGuide

Seite 71 - Caution: Set to UAC type

ACP4-34. ReferenceUTP cable connection chartThe Unshielded Twisted Pair (UTP) cable isa sort of the signal line connecting the LANenvironment. Two cop

Seite 72

P/No.: MFL37115820After reading this manual, keep it in a place easily accessible to the user for future reference.Printed in Korea

Seite 73 - Possible to check the set

Installation/Owner's Manual2-32. Installing ACPWhen one ACP is used as web server, the ACP should be connected with the network structure asshown

Seite 74

ACP2-4ONL1 2 3 4KSDO4HONL1 2 3 4KSDO4H00 01 02103031323311 12Multi VPI485ONL1 2 3 4KSDO4HMulti VPI485ONL1 2 3 4KSDO4HMulti

Seite 75

Installation/Owner's Manual2-52. Installing ACPWhen one ACP is connected to the AC Manager without the hub, the ACP should beconnected with the n

Seite 76

2ACPAdvanced Control PlatformContents1. ACP FUNCTIONS & SPECIFICATION ...1-1Functions of ACP ...

Seite 77 - Modify the setting

ACP2-62. Installing ACPNot using the hubIf it is connected without the hub, the network can be configured as shown at the following example.ONL1 2

Seite 78

Installation/Owner's Manual2-72. Installing ACPWhen more than one ACP are connected to the AC Manager via the hub, the ACP should beconnected wit

Seite 79 - However, we recommend to use

ACP2-82. Installing ACP10303111 1200 01 02LG-NET 1MENU/SELECTTXRXLG-NET 2TXRXLG-NET 3TXRXLG-NET 4TXRXEthernet 1ACTLNKEthernet 2ACTLNKConsoleRunPowerTX

Seite 80 - [OK] button

Installation/Owner's Manual2-92. Installing ACPSetting address with wired remote controllerTimer CancelProgram WeekHour MinHolidaySet/ClrRESETZON

Seite 81

ACP2-102. Installing ACPYou can set the address of the indoor unit through thewireless remote controller that controls the indoorunit. To set the addr

Seite 82

Installation/Owner's Manual2-112. Installing ACPON OFFSETCANCELPLASMAInformation: Checking the set addressYou can check the set address by using

Seite 83 - Accessing the ACCS

ACP2-122. Installing ACPSetting the PI485 and Connecting the cableAfter setting the address of the indoor unit, install the PI485 and set the DIP swit

Seite 84

Installation/Owner's Manual2-132. Installing ACPTip: Checking the PI485 DIP switch settingIt can be checked whether the indoor unit address and t

Seite 85

ACP2-142. Installing ACPConnecting the 2PIN connectorIf you want to use the individual lock function for setting mode, wind flow, and temperature lock

Seite 86

Installation/Owner's Manual2-152. Installing ACPThe following figure shows the example of the central control for connecting the 2PIN connector t

Seite 87 - LG ACCS window buttons

Installation/Owner's Manual33. ACP OPERATION BY USING THE LG ACCS...3-1Setting the functions of the ACP ...

Seite 88 - Current time window

ACP2-162. Installing ACPConnceting RS485 cable to PI485In order to connect the PI485 and the ACP, two RS485 cables should be connected to the BUS_A an

Seite 89

Installation/Owner's Manual2-172. Installing ACPThe following figure shows the example for connecting more than one PI485 to one ACP.+10V GNDBUS_

Seite 90

ACP2-182. Installing ACPTip: Connection setup when using the simple central controller together with the ACPThe simple central controller can be used

Seite 91

Installation/Owner's Manual2-192. Installing ACPInstalling the ACP and Connecting the cableAfter setting the PI485, the ACP should be installed a

Seite 92 - Select/Deselect All button

Caution: Connecting the RS485 communication cableBecause the connection of the RS485 communication cable has a polarity, be carefulthat the connection

Seite 93

Installation/Owner's Manual2-212. Installing ACPTip: Connecting the RS485 of the ACP64 outdoor units at maximum can be connected to one port of t

Seite 94

ACP2-222. Installing ACPThe following figure shows the example of the incorrect connection of the RS485 of the ACP.Simple central controllerMulti VPI4

Seite 95

Installation/Owner's Manual2-232. Installing ACPConnecting Ethernet cable to ACPAfter connecting the ACP and the RS485 cable, the Ethernet cable

Seite 96 - Controlling the ventilator

ACP2-242. Installing ACPLG-NET 1MENU/SELECTTXRXLG-NET 2TXRXLG-NET 3TXRXLG-NET 4TXRXEthernet 1ACTLNKEthernet 2ACTLNKConsoleRunPowerTXRXFDDTXRXExt. TXRX

Seite 97

Installation/Owner's Manual2-252. Installing ACPConfiguring the ACP networkAfter connecting the ACP to various devices via the cable, the network

Seite 98

ACP4Note for safetyNote for safetyIn order to prevent the user's injury or the damage of the product, keep the followings to use theproduct. The

Seite 99

ACP2-262. Installing ACPLG-NET 1MENU/SELECTTXRXLG-NET 2TXRXLG-NET 3TXRXLG-NET 4TXRXEthernet 1ACTLNKEthernet 2ACTLNKConsoleRunPowerTXRXFDDTXRXExt. TXRX

Seite 100 - Operation mode

Installation/Owner's Manual2-272. Installing ACPEntering into the environment setup modePress 'MENU/SELECT' button of the ACP to enter

Seite 101 - Note: Additional function

ACP2-282. Installing ACPHow to set the network addressThe network address consists of four 3-digit numbers. In case of setting the network address, th

Seite 102

Installation/Owner's Manual2-292. Installing ACPSetting the IP addressIn order for the user to use the functions of the ACP via the web, the uniq

Seite 103 - Setting the schedule

ACP2-30Setting the gateway address2. Installing ACPAfter setting the IP address, the gateway address should be set. Set the gateway address as follows

Seite 104 - Pattern setup button

Installation/Owner's Manual2-312. Installing ACPSetting the netmask addressAfter setting the gateway address, the netmask address should be set.

Seite 105 - Mode change button

ACP2-322. Installing ACPChecking the network environmentWhen the IP address, the gateway address, and the netmask address are set, the essential netwo

Seite 106

Installation/Owner's Manual2-332. Installing ACPSetting the functions of the ACPThe following functions can be set by using the menu of the ACP:•

Seite 107 - Schedule control setup window

ACP2-342. Installing ACPSelecting Peak or DemandThe ACP offers the function to manage the wattage consumed by the connected air conditioner, bywhich t

Seite 108 - Air flow

Installation/Owner's Manual2-352. Installing ACP2. Use Up/Down ( , ) button to set the desired wattage control method. Press the Up ( ) button to

Seite 109 - Schedule display window

Installation/Owner's Manual5Note for safetyAny question about theproduct should be asked tothe service center or theprofessional installationagen

Seite 110 - Save the setting button

ACP2-362. Installing ACPSelecting ACCS display languageThe ACP offers the web server function. So, when the user accesses the ACP by using the Interne

Seite 111

Installation/Owner's Manual2-372. Installing ACP2. Use Up/Down ( , ) button to set the desired language. Press the Up ( ) button to display inEng

Seite 112 - Date selection window

ACP2-382. Installing ACP2. Use Up/Down ( , ) button to set whether to use the schedule function or not. Press the Up ( )button to use the schedule fun

Seite 113 - Stop All window

Installation/Owner's Manual2-392. Installing ACP3. When the 'MENU/SELECT' button is pressed, whether to use the schedule function or no

Seite 114 - Chick View mode to switch

ACP2-402. Installing ACP2. Use Up/Down ( , ) button to set whether to use the wattage display function or not. Press the Up() button to use the wattag

Seite 115

Installation/Owner's Manual2-412. Installing ACP3. When the 'MENU/SELECT' button is pressed, whether to use the wattage display functio

Seite 116

ACP2-422. Installing ACPSetting error history displayLG ACCS, operating program of ACP, provides error history function to monitor various types of er

Seite 117

2. Installing ACPInstallation/Owner's Manual2-43Configuring the ACCS accessThe user can use the LG ACCS program at the computer connected with th

Seite 118

2. Installing ACPACP2-443. After selecting the [Advanced] tab at the 'Internet Option' window, check whether there is the'Microsoft VM&

Seite 119

2. Installing ACPInstallation/Owner's Manual2-45Checking the MS Explorer security settingFor the stable operation of the LG ACCS (Advanced Centra

Seite 120

ACP6Note for safetyDo not install the product at the wet place.• It may cause to degrade the insulating ability and may cause fire.LG-NET 1MENU/SELECT

Seite 121

2. Installing ACPACP2-463. After selecting the [Security] tab at the 'Internet Option' window, press [Custom Level] at thebottom. 'Secu

Seite 122

2. Installing ACPInstallation/Owner's Manual2-475. After selecting 'Edit Right' tab at the Internet window, set 'Run Unsigned Cont

Seite 123

2. Installing ACPACP2-487. Finally, press [OK] button at the 'Internet Options' window. Now, the security setup to use the LGACCS is complet

Seite 124

2. Installing ACPInstallation/Owner's Manual2-49Entering the indoor unit & ventilator informationWhen the installation at the previous steps

Seite 125 - Click [Exit the exception

2. Installing ACPACP2-50If the ACP is not connected to the AC ManagerWhen the ACP is not connected to the AC Manager, the information of the indoor un

Seite 126

2. Installing ACPInstallation/Owner's Manual2-512.When the IP address is correctly entered, the following LG ACCS Login screen is displayed. Ente

Seite 127

2. Installing ACPACP2-524. When the login is successfully done, the initial screen of the LG ACCS is displayed as shown at thebelow. Click [System set

Seite 128 - Wattage monitor

2. Installing ACPInstallation/Owner's Manual2-53Setting the air conditionerSet the indoor unit of the air conditioner as follows. The setup metho

Seite 129 - Operation switching period

2. Installing ACPACP2-543. Click [Default input] button. The outdoor unit information (group number) is automatically entered.4.Except the outdoor uni

Seite 130 - Desired operation ratio

2. Installing ACPInstallation/Owner's Manual2-55Item DescriptionG/W No. Leave as it is with no setting.Outdoor unit No. (Group No.)Enter the numb

Seite 131 - Peak excluded air conditioner

Installation/Owner's Manual7Note for safetyCAUTIONIf the product is flooded,consult the service centre orthe professional installationagency.• It

Seite 132 - Note: Setting the peak

2. Installing ACPACP2-566. When you click [Done] button, 'Outdoor unit information input' window is closed and it returns tothe previous scr

Seite 133 - Controlling the demand power

2. Installing ACPInstallation/Owner's Manual2-578. Enter the air conditioner group name and the information of the indoor unit. When each display

Seite 134

2. Installing ACPACP2-58Dip switch DescriptionPhysical address Enter the physical address of the indoor unit. The physical addressconsists of three nu

Seite 135

2. Installing ACPInstallation/Owner's Manual2-5911. The saving process is performed. When the air conditioner setup is successfully done, the gro

Seite 136

Note: Physical and Logical groupAt the ACP, the connected air conditioners can be grouped by using the concept “Physical group”and “Logical group.” Th

Seite 137

2. Installing ACPInstallation/Owner's Manual2-61Setting the ventilatorSet the ventilator as follows. In this case, the method for setting the ven

Seite 138

2. Installing ACPACP2-623. Click [Default input] button. The group number (outdoor unit number) is automatically entered.4.Leave the item(s) as many a

Seite 139

2. Installing ACPInstallation/Owner's Manual2-635. Enter the setting value suitable to each item. When the item to be set is clicked, the related

Seite 140 - Reviewing the error history

2. Installing ACPACP2-646. When [Done] button is clicked, 'Outdoor unit information input' window is closed and it returns tothe previous sc

Seite 141 - Saving and Printing

2. Installing ACPInstallation/Owner's Manual2-658. Enter the ventilator group name and the information of the ventilator. When each displayed ite

Seite 142 - Error history list

ACP1-11. ACP Functions & SpecificationFunctions of ACP1. ACP Functions & SpecificationThe ACP(Advanced Control Platform) is the central contro

Seite 143

2. Installing ACPACP2-669. For the remaining one group, set the number of the ventilators and the item by the procedure sameto Step 7 and 8.10. When a

Seite 144

2. Installing ACPInstallation/Owner's Manual2-67Air conditioner is not found at the ACCS of the ACPThe LED of the LG-NET of the ACP blinks?Reche

Seite 145 - Group list

2. Installing ACPACP2-68Monitoring the ACP condition after the lock all and the temperature lockExecute the LG ACCS of the ACP to select all indoor un

Seite 146 - 'Start' calendar

3. ACP operation by using the LG ACCSThe LG ACCS is the UI program of the web server which can operate the ACP. This chapterdescribes the function and

Seite 147 - Apply & Cancel button

3. ACP operation by using the LG ACCSACP3-22. When the IP address is correctly entered, the following LG ACCS Login screen is displayed. Enterthe ID a

Seite 148 - Setting the system

3. ACP operation by using the LG ACCSInstallation/Owner's Manual3-34. The initial screen of the LG ACCS is displayed as shown at the below. When

Seite 149

3. ACP operation by using the LG ACCSACP3-4Reviewing the initial ACCS screenThe LG ACCS(Advanced Centralized Control System) is the program which is a

Seite 150 - Default input button

3. ACP operation by using the LG ACCSInstallation/Owner's Manual3-5Menu selection buttonsYou can select the menu at the menu selection button to

Seite 151

3. ACP operation by using the LG ACCSACP3-6Message windowIt displays the message about the operation information and the error information of the indo

Seite 152

3. ACP operation by using the LG ACCSInstallation/Owner's Manual3-7Controlling the air conditionerYou can use the LG ACCS to control the function

Seite 153 - Temporary saving window

Installation/Owner's Manual1-21. ACP Functions & SpecificationBuilt-in Web serverVarious functions of contents can be used when the IP addres

Seite 154

3. ACP operation by using the LG ACCSACP3-8Air conditioner operation status windowIt displays the operation status of each air conditioner, the operat

Seite 155 - Caution: Delete ventilator

3. ACP operation by using the LG ACCSInstallation/Owner's Manual3-9Current & desired temperatureItem Icon DescriptionThe current air conditi

Seite 156 - Time synchronization button

3. ACP operation by using the LG ACCSACP3-10Selecting the air conditioner group or the air conditioner windowThis window displays the list of the air

Seite 157 - Last save state button

Installation/Owner's Manual3-113. ACP operation by using the LG ACCSControlling & monitoring the air conditioner windowIt displays the air co

Seite 158 - Save button

3. ACP operation by using the LG ACCSACP3-12Air flow DescriptionIt sets to ventilate with a small of air flow.It sets to ventilate at the medium level

Seite 159

3. ACP operation by using the LG ACCSInstallation/Owner's Manual3-13Operate the air conditioner according to the set value.Stop the operating air

Seite 160 - Troubleshooting

3. ACP operation by using the LG ACCSACP3-14Controlling the ventilatorYou can use the LG ACCS to control the functions such as selecting the ventilati

Seite 161 - EEPL library

3. ACP operation by using the LG ACCSInstallation/Owner's Manual3-15clicking them. The list of the ventilator(s) belonging to a specific ventilat

Seite 162 - UTP cable connection chart

3. ACP operation by using the LG ACCSACP3-16Ventilator operation status windowThis window displays the information such as operation mode of each vent

Seite 163 - Printed in Korea

3. ACP operation by using the LG ACCSInstallation/Owner's Manual3-17Air flowLockAdditional functionsThe air flow from the ventilator is displayed

Kommentare zu diesen Handbüchern