LG PHLTA.ENCXLEU Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Nein LG PHLTA.ENCXLEU herunter. LG PHLTA.ENCXLEU Owner's manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 1
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
MODELS: PHLTA, PHLTC
Do not drop water on to the product. It may
cause an electric shock or product
breakdown.
If the product was submerged under water,
ask the service center for instruction. It may
cause fire or an electric shock unless you
do that.
For electrical work, contact the dealer,
seller, a qualified electrician, or Authorized
Service Center.
Safety Precautions
Use the original parts in order to prevent
fire, an electric shock, explosion, and
product breakdown.
Keep combustible and/or inflammable
materials away from the product in order to
prevent fire or product breakdown.
ELB(Earth Leakage Circuit Breaker)should
be Installed for safety.
Entrust installation of the product to the
service center because improper
installation may cause fire, an electric
shock, explosion, and physical injury.
Do not disassemble, repair, or modify the
product at your discretion in order to
prevent fire or an electric shock.
Do not install the product in wet and humid
areas in order to prevent product
breakdown.
Installation
WARNING
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by
the following indications.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
Safety Precautions
Make sure children or senor
citizens use the product
under proper observation in
order to prevent safety
accident.
Do not subject the product
to shock. It will cause
product breakdown.
Do not pick the product with
a sharp tool. It may cause
product breakdown with the
damage to its parts.
Do not clean the product with strong
cleanser such as solvent. Use soft clothes
in order to prevent fire or product
deformation.
Do not touch the product with a wet hand.
Do not pull the lead cable. It may cause
product breakdown or an electric shock.
CAUTION
Part Description
Part Description
Thermistor sensor
12m(1EA)
Fixing screw for
Remote Sensor(2EA)
ELB(MCCB) & Relay contactor
Installation
1 Phase Relay Bracket
Ralay Scerw (2EA)
3 Phase Relay Bracket
Manual Cable 4EA
(For connecting ELB(MCCB)
with terminal block)
Installation Method
Installation Method
How to Install Sanitary Water Tank Kit
Follow below procedures Step 1 ~ Step 5.
Step 1. Find magnetic switch and ELB(MCCB) in the kit. Fit them into the indoor unit
control box with enclosed a braket and screws. (symbol ʶ at picture)
Step 2. Connect ‘CN_B/HEAT(A)’ (White Connector) of the indoor unit PCB with
magnetic switch contact using enclosed cable (symbol ʷ at the picture).
Connect magnetic switch contactor port no. A1 and A2.
Step 3. Connect magnetic switch contactor port no. L1 and L3 with ELB(MCCB) port
no. 2 and 4.(symbol ʸat the picture).
Check Polarity
• Connect magnetic switch contact port no. L1 to ELB(MCCB) port no. 2
• Connect magnetic switch contact port no. L3 to ELB(MCCB) port no. 4
Step 4. Connect Magnetic switch contactor port no. T1 and T3 with terminal block 1
port 6 and 7. (symbol ʹat the picture).
Check Polarity
• Connect magnetic switch contact port no. T1 to terminal block 1 port 6
• Connect magnetic switch contact port no. T3 to terminal block 1 port 7
Step 5. 1Ø Electric Heater
Connect ELB(MCCB) port no. 1 and 3 with block 3 Port 3 and 4.(symbol E at
the picture).
3Ø Electric Heater
Connect ELB(MCCB) port no. 1 and 3 with block 3 Port 1 and 2.(symbol E at
the picture).
Check Polarity
• Connect ELB port no. 1 to terminal block 3 port 3
• Connect ELB port no. 3 to terminal block 3 port 4
• Connect MCCB port no. 1 to terminal block 3 port 1
• Connect MCCB port no. 3 to terminal block 3 port 2
CAUTION
Installation Method
Relay contactor
port no. assignment
1
3
2 4
ELB(MCCB)
port no. assignment
0
1
2
6
4
8
3Ø Electric Heater1Ø Electric Heater
ʶ
ʹ
ʸ
ʶ
ʺ
Terminal
Block 3
Terminal
Block 1
ʸ
ʶ
ʶ
ʷ
ʹ
ʺ
Terminal
Block 1
Terminal
Block 3
Installation Method
Step 6. Find sanitary water tank sensor. Connect it to ‘CN_TH4’ (Red Connector) of the
indoor unit PCB. The sensor wire should be passed through sensor holes. The
sensor should be mounted correctly to the sensor hole of sanitary water tank.
Sensor mounting
Insert sensor into sensor socket and bolt it tightly.
CAUTION
Sanitary Water
(Thermistor sensor)
Tank
Seitenansicht 0
1

Inhaltsverzeichnis

Seite 1 - Installation Method

MODELS: PHLTA, PHLTCDo not drop water on to the product. It maycause an electric shock or productbreakdown.If the product was submerged under water,as

Kommentare zu diesen Handbüchern

Keine Kommentare