LG M3704CCBA Bedienungsanleitung Seite 56

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 90
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 55
Controlling the Multiple Product
RS-232C
A1
Controlling the Multiple Product
RS-232C
A1
A1
Connecting the cable
Connect the RS-232C cable as shown in the picture.
You need to purchase a cable to connect the RS-232C socket as it is not provided as the
accessory.
The RS-232C protocol is used for communication between the PC and product. You can
turn the product on/off, select an input source or adjust the OSD menu from your PC.
Use this method to connect several products to a single PC. You can control several products at a
time by connecting them to a single PC.
If the [Set ID] menu in [Option] is set to OFF, the monitor ID value should be set between 1 and 99.
RS-232C Cable
(not included)
monitor 1
PC
monitor 2
monitor 3 monitor 4
7-Wire Configurations (Standard RS-232C cable)
RXD
TXD
GND
DTR
DSR
RTS
CTS
TXD
RXD
GND
DSR
DTR
CTS
RTS
PC Monitor
2
3
5
4
6
7
8
3
2
5
6
4
8
7
D-Sub 9 D-Sub 9
(Female) (Female)
3-Wire Configurations (Not Standard)
RXD
TXD
GND
DTR
DSR
RTS
CTS
TXD
RXD
GND
DTR
DSR
RTS
CTS
PC Monitor
2
3
5
4
6
7
8
3
2
5
6
4
7
8
D-Sub 9 D-Sub 9
(Female) (Female)
►Baud Rate : 9600 buad Rate (UART)
►Data Length : 8 bit
►Parity Bit : None
►Stop Bit : 1bit
►Flow Control : None
►Communication Code : ASCII code
►Use a crossed (reverse) cable
Communication Parameter
RS-232C Configurations