Seitenansicht 0
Date:
JobName/Location:
PONo.:
Architect:
Engr:
GC:
Rep:
For:
File
A
pp
roval
Mech:
Resubmit
Other
Tag#:
(Company)
(ProjectManager)
ArtCool™PremierSingleZoneInverter
LA120HYV1
Performance:
Capacity(Btu/h)
11,000
SEER
25.5
EER
13.75
Cooling:
Heating:
Capacity(Btu/h)
12,000
HSPF
12.0
CoolingNominalTestConditions: HeatingNominalTestConditions:
Indoor:
80°FDB/67°FWB
Indoor:
70°FDB/60°FWB
Outdoor:
95°FDB/75°FWB
Outdoor:
47°FDB/43°FWB
Electrical:
MCA(A )
11.2
MOP(A)
15
Compressor(A)
8.3
FanMotor (A)
0.40
OutdoorUnit:
CoolingRatedAmps(A)
8.70
HeatingRatedAmps(A)
8.70
CoolingPowerInput(kW)
0.80
HeatingPowerInput(kW)
0.75
Piping:
LiquidLine(in,OD)
1/4
AdditionalRefrigerant(oz/ft)
0.22
MaxElevation(ft)
32.8
PipingLengt h(noadd'lrefrigerant,ft)
41.0
ControlsFeatures:
•24-Houron/offmer
•4-W ayautoswing
•Autochangeover
•Autorestart
•Built-inlowambient
operationto14°F
•Chaoswind
•Selfdiagnosis
•Sleepmode
•Sodryoperaon
•Ultraquietoperaon
•Coolingonlyswitch
•3MMicroProtectionFilter
•SmartACmodule
Page1of3
Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice.
©LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lghvac.com
PowerSupply(V¹/H z/Ø)
208-230/60/1
VaporLine(in,OD)
3/8
OperatingRange:
OutdoorUnit:
Cooling(°FDB)
14-118
Heating(°FWB)
-13- 65
Cooling(°FWB)
53-75
Heating(°FDB)
60-86
IndoorUnit :
UnitData:
RefrigerantType
R410A
RefrigerantCharge(lbs)
2.54
Fan:
Notes:
1.Acc eptableoperangvoltage:187V-253V.
2.Pipinglengthsareequiva lent.
3.SoundPressurelevelsaretestedinananechoicchamberunderISOStandard1996.
4.Allpower/communicaoncabletobeminimum18AWG,4-conductor,stranded,shielded
andmustcomplywithapplicablelocalandnationalcode.
5.SeeEngineeringManua lforsensiblean
dlatentcapacies.
6.Powerwiring cab lesizemustcomplywiththeapplicablelocalandnaonalcode.
7.Theindoorunitcomeswithadryheliumcharge.
8.Thisdataisra te d 0abovesealevel,with24.6ofrefrigerantlineanda0level
differe ncebetweenoutdoorandindoorunits.
9.
MustfollowinstallaoninstruconsintheapplicableLGinstallaonmanual.
ODUType
Propeller
IDUType
CrossFlow
Motor/Drive
BrushlessDigitallyControlled/Direc
t
Dehumidification(pts/hr)
3.6
RefrigerantControl
EEV
HeatExchangerCoating
GoldFin™
ODUNetUnitWeight(lbs)
77
ODUShippingWeight(lbs)
82
IDUNetUnitWeight(lbs)
24
IDUShippingWeight(lbs)
30
FanSpeeds(Fan/Cooling/Heating)
6/6/ 6
Quantity(ODU+IDU)
1+1
IDUAirFlowH/M/L(CFM)
494/417/ 283
ODUMaxAirFlowRate(CFM)
1,165
IDUSoundPressure(H/M/L/Sleep)±3dB(A) ³
42/36/ 25/17
ODUSoundPressure(Max)±3dB(A)³
45
O
p
tionalAccessories
(
soldse
p
aratel
y)
:
•Condensatesensor
connection
•Defrostcontrol
•Dehumidifyingmode
•Hotstart
•Jetcool/Jetheat
•Selfcleaningindoorco il
SB-SingleZonePremier-LA120HYV1-02-15
IndoorUnit(IDU)-LAN120HYV1OutdoorUnit(ODU)-LAU120HYV1
SEER-SeasonalEnergyEfficiencyRatio EER-EnergyEfficiencyRatio
HSPF-HeatingSeasonalPerformanceFactor
MOP-MaximumOvercurrentProtection MCA-MinimumCircuitAmpacity
DryCon tactforthirdpartythermostat-PDRYCB300
LGProgrammableThermostat-PREMTB10U
TotalPowerInput:
Min/MaxPipeLength(ft)²:
6.6
/
65.6
Foracompletelistofavailableaccessories,contactyourLGrepresentative.
Seitenansicht 0
1 2 3

Inhaltsverzeichnis

Seite 1 - LA120HYV1

Date:JobName/Location:PONo.:Architect:Engr:GC:Rep:For:FileApprovalMech:ResubmitOtherTag#:(Company)(ProjectManager)ArtCool™PremierSingleZoneIn

Seite 2 - JobName/Location:

JobName/Location:Ta g#:Date:PONo.:ArtCool™PremierSingleZoneInverterPage2of3Forcontinualproductdevelopment,LGreservestherighttochan

Seite 3 - ‐LAN120HYV1

JobName/Location:Tag#:Date:PONo.:ArtCool™PremierSingleZoneInverterIndoorUnit(IDU)‐LAN120HYV1Page3of3Forcontinualproductdevelopment,

Kommentare zu diesen Handbüchern

Keine Kommentare