LG LSA3AB3VT1 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Mobile Klimaanlagen LG LSA3AB3VT1 herunter. LG LSA3AW3VT1 Owner’s Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 48
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
LG Electronics India Pvt. Ltd.
Registered Office: Plot No. 51, Surajpur Kasna Road, Greater Noida - 201 306 (U.P.) INDIA Tel: 0120-2560900 Fax: 0120-2560957
P/No.: MFL39754829
Please read this manual carefully before operating the unit.
Owner's Manual
Seitenansicht 0
1 2 3 4 5 6 ... 47 48

Inhaltsverzeichnis

Seite 1 - Owner's Manual

LG Electronics India Pvt. Ltd.Registered Office: Plot No. 51, Surajpur Kasna Road, Greater Noida - 201 306 (U.P.) INDIA Tel: 0120-2560900 Fax: 0120-25

Seite 2 - TABLE OF CONTENTS

10 Room Air ConditionerIntroductionIntroductionThis symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause

Seite 3 - Safety Precautions

Owner's Manual 11Electrical SafetyElectrical Safety• This appliance must be properly grounded.To minimize the risk of electric shock, you must a

Seite 4 - 4 Room Air Conditioner

12 Room Air ConditionerOperating InstructionsHow to insert the BatteriesStorage and Tips for using the Remote Controller1. Remove the battery cover by

Seite 5 - Owner's Manual 5

Owner's Manual 13Operating InstructionsRemote Control OperationsThe remote control transmits the signals to the system.Features of the Remote Co

Seite 6 - 6 Room Air Conditioner

Features of the Remote Control- Door Opened1ON/OFF TIMER BUTTONSUsed to set the time of starting and stoppingoperation.2TIME SETTING BUTTONSUsed to ad

Seite 7 - Owner's Manual 7

ONA/SWINGOP WERTEMPFAN SPEEDO LJET C OONCoolingHealthyDehumidificationHeating(Heat pump model only)To lower the temperatureTo raise the temperatureOpe

Seite 8 - 8 Room Air Conditioner

(Heat pump model only)HeatingCoolingTo lower the temperatureTo raise the temperatureOperating InstructionsPress the Start/Stop button. The unit will r

Seite 9 - Prior to Operation

A/SWINGOPWERTEMPFAN SPEEDJET COOLONONOwner's Manual 17CoolingHealthyDehumidificationHeating(Heat pump model only)Operating InstructionsPress the

Seite 10 - Introduction

ONA/SWINGPOWERTEMPFAN SPEEDJET COOLON18 Room Air ConditionerCoolingHealthyDehumidificationHeating(Heat pump model only)To lower the temperatureTo rais

Seite 11 - Electrical Safety

Owner's Manual 19or orOperating Instructionsq During the JET COOL function at any moment, the A/C starts to blow the cool air at extremelyhigh s

Seite 12 - Operating Instructions

Room Air Conditioner Owner’s ManualTABLE OF CONTENTS2 Room Air ConditionerSafety Precautions...3Prior to Operation ...

Seite 13 - Remote Control Operations

20 Room Air ConditionerOperating InstructionsPress the Start/Stop button.The unit will respond with abeep.1Open the door of the remotecontroller. Pres

Seite 14 - 14 Room Air Conditioner

Owner's Manual 21Operating InstructionsPress the Start/Stop button. The unit will respond with a beep.Open the door of the remote controller and

Seite 15 - Cooling operation

22 Room Air ConditionerDelay OFF Timer Delay ON Timer Delay OFF and ON Timer Delay ON and OFF TimerOperating InstructionsSleep mode1. Press the Sleep

Seite 16 - Auto Operation

Owner's Manual 23Fan speed is on low. Fan speed is on medium. Fan speed is on high.CHAOS AirOperating InstructionsVertical Airflow Direction Con

Seite 17 - Owner's Manual 17

24 Room Air ConditionerAUTO CLEANOperating Instructionsq During Auto Clean function, moisture left in indoor units after Cooling Operation or HealthyD

Seite 18 - 18 Room Air Conditioner

Owner's Manual 25Operating InstructionsHighSpeedHelpful informationFan speed and cooling capacity.The cooling capacity indicated in the specific

Seite 19 - Jet cool operation

26 Room Air ConditionerMaintenance and ServiceMaintenance and ServiceIndoor UnitBefore performing any maintenance, turn off the main power to the syst

Seite 20 - 20 Room Air Conditioner

(Side)(Rear)Air intakeventsAir outletventsPipingDrain Hose(Side)(Rear)Air intakeventsAir outletventsPipingDrain Hose(Side)(Rear)Air intakeventsAir out

Seite 21 - 2nd F operation

Maintenance and ServiceCommon Problems and SolutionsBefore calling for serviceIf you have problems with your air conditioner, read the following infor

Seite 22 - Additional Features

Operate the air conditioner on Air circulationmode (Refer to page 23) for 2 to 3 hours.• This will dry out the internal mechanisms.When air conditione

Seite 23 - Air circulation mode

Owner's Manual 3Safety PrecautionsSafety PrecautionsTo prevent the injury of the user or other people and property damage, the following instruc

Seite 24 - Auto clean (Optional)

?Before you call for service...Check the following points before requesting repairs or service... If the fault persists, pleasecontact your dealer or

Seite 25 - Test operation

Email : [email protected] ElectronicsFor any further information, please contact LGEIL BranchesBRANCH BRANCH OFFICE ADDRESSSTD CODEPHONE NO. / F

Seite 27 - DEODORIZING

TEST RUNNINGTEST RUNNING16BoltTubing connectionCheck that all tubing and wiring have beenproperly connected.Check that the gas and liquid side service

Seite 28 - Common Problems and Solutions

15Gas sideLiquid sideCapHexagonal wrench2-way valve(Open)3-way valve(Close)CEvacuationSoap water methodRemove the caps from the 2-way and 3-wayvalves.

Seite 29 - Operation Tips

14AIR PURGINGAIR PURGINGLo HiIndoor unitOutdoor unitManifold valveCharge hoseNitrogen gascylinder(in verticalstanding position)Pressure gauge11111122A

Seite 30 - Case Explanation See page

TapingDrainhosePipingsConnectingcableTip of drain hose dipped in waterWaterleakageDitchLess than 50mm gapDownward slopeCHECKING THE DRAINAGE AND FORMI

Seite 31 - Email : [email protected]

1211Connect the cable to theoutdoor unit22ARemove the control cover from the unit byloosening the screw.Connect the wires to the terminals on thecontr

Seite 32

CONNECTING THE CABLE BETWEEN INDOOR UNIT AND OUTDOOR UNITCONNECTING THE CABLE BETWEEN INDOOR UNIT AND OUTDOOR UNIT11Connect the cable fromIndoor to ou

Seite 33 - TEST RUNNINGTEST RUNNING

Capacity(Btu/h)Pipe Size[Torque]GAS LIQUID18K, 24K, 26K.1/2"[5.5kg m].5/8"[6.6kg m].1/4"[1.8kg m].3/8"[4.2kg m]Bundle the piping

Seite 34 - Finishing the job

4 Room Air ConditionerSafety PrecautionsBe cautious whenunpacking and installingthe product. • Sharp edges could cause injury.Be especially careful of

Seite 35 - AIR PURGINGAIR PURGING

Vinyl tape(narrow)Connecting cablePipeConnectionpipeVinyl tape(wide)Wrap with vinyl tapeIndoor unit pipePlastic bandsInsulation materialVinyl tape(nar

Seite 36 - Form the piping

Vinyl tape(narrow)Connecting cablePipeConnectionpipeVinyl tape(wide)Wrap with vinyl tapeIndoor unit pipeDrain pipeConnecting cableWrap with vinyl tape

Seite 37 - Connect the cable to the

22Connection of piping--IndoorPreparing the indoor unit's piping and drainhose for installation through the wall.Remove the p la st ic t

Seite 38 - Indoor to outdoor unit

FLARING WORK AND CONNECTION OF PIPINGFLARING WORK AND CONNECTION OF PIPING11Flaring workMain cause for gas leakage is due to defect inflaring work. Ca

Seite 39 - Connection of the

33How to fix installation plateMount the installation plate horizontally byaligning the centerline using a level.AMount the installation plate on the

Seite 40 - GAS LIQUID

INSTALLATION OF INDOOR, OUTDOOR UNITINSTALLATION OF INDOOR, OUTDOOR UNIT4More than 10cm More than 10cmMore than 60cmMore than 60cmMore than 70cm1122Re

Seite 41 - Indoor unit drain hose

THE FOLLOWING SHOULD BE ALWAYS OBSERVED FOR SAFETYTHE FOLLOWING SHOULD BE ALWAYS OBSERVED FOR SAFETYBe sure to read "THE FOLLOWING SHOULD BE ALWA

Seite 42 - --Indoor

INSTALLATION OVERVIEWInstallationRequirementsRequired Parts Required ToolsConnecting the cable betweenindoor unit and outdoor unit11...

Seite 43 - Flaring work

LG Electronics India Pvt. Ltd.Registered Office: Plot No. 51, Surajpur Kasna Road, Greater Noida - 201 306 (U.P.) INDIA Tel: 0120-2560900 Fax: 0120-25

Seite 44 - Drill a hole in the wall

Owner's Manual 5Safety PrecautionsUse a dedicated outlet forthis appliance. • There is risk of fire or electricalshock.Grasp the plug to removet

Seite 45 - Piping length and elevation

6 Room Air ConditionerSafety PrecautionsAlways check for gas(refrigerant) leakage afterinstallation or repair ofproduct. • Low refrigerant levels mayc

Seite 46

Owner's Manual 7Safety PrecautionsDo not install the productwhere the noise or hot airfrom the outdoor unit coulddamage the neighborhoods. • It

Seite 47 - INSTALLATION OVERVIEW

8 Room Air ConditionerSafety PrecautionsDo not recharge or disassemble thebatteries. Do not dispose of batteries in afire. • They may burn or explode

Seite 48 - Installation Instructions

Owner's Manual 9Prior to OperationPrior to Operation1. Contact an installation specialist for installation.2. Plug in the power plug properly.3.